Back

KEW 1012

Price : 0/Piece(s)
Minimum Order : 1 Piece(s)
Production Capacity : 1 Piece(s)/week
Kyoritsu KEW India Instruments Pvt. Ltd.

Ahmedabad

Visit Exhibitor Profile
Product Description

KEW 1012

Photos

  • Features

  • True RMS can measure and indicate distorted waveforms
  • 6040 counts with Bar Graph display
  • MIN/MAX function enables to record min & max value
  • REL(relative value) function to indicate the measurement variation
  • Product Description

    DC V
    600.0mV/6.000/60.00/600.0/600V (Input Impedance: 10MΩ, 100MΩ only 600mV) ±0.5%±2dgt (600.0mV/6.000/60.00/600.0V) ±0.8%±3dgt (600V)
    AC V
    6.000/60.00/600.0/600V (Input Impedance: 10MΩ) ±1.5%±5dgt (6.000V) ±1.2%±3dgt (60.00/600.0V) ±1.5%±5dgt (600V)
    DC A
    600/6000µA/60/600mA/6/10A ±1.2%±3dgt (600/6000µA/60/600mA) ±2.0%±5dgt (6/10A)
    AC A
    600/6000µA/60/600mA/6/10A ±1.5%±4dgt (600/6000µA/60/600mA) ±2.2%±5dgt (6/10A)
    Ω
    600Ω/6/60/600kΩ/6/60MΩ ±1.0%±2dgt, (600Ω/6/60/600kΩ/6MΩ) ±2.0%±3dgt (60MΩ)
    Continuity buzzer
    0 – 600Ω (Buzzer sounds below 100Ω)
    Diode test
    2.8V Release Voltage:Approx. 0.4mA Test Current
    Capacitance
    40/400nF/4/40/400/4000µF
    Frequency
    10/100/1000Hz/10/100/1000kHz/10MHz
    DUTY
    0.1 – 99.9% (Pulse width/Pulse period) ±2.0%±2dgt (- 10kHz)
    Applicable standards
    IEC 61010-1 CAT III 300V Pollution degree 2, IEC 61010-1 CAT II 600V Pollution degree 2, IEC 61010-031, IEC 61326
    Display
    6040 Counts
    Power source
    R6 (1.5V) × 2 (Auto-power-OFF within 15 minutes)
    Dimensions
    161(L) × 82(W) × 50(D)mm
    Weight
    Approx. 280g
    Included Accessories
    7066A (Test leads) 0.8A/600V (Ceramic Fuse) × 1built-in 10A/600V (Ceramic Fuse) × 1built-in R6 × 2 Instruction Manual
    Optional Accessories
    7234 (Crocodile clip test lead) 9095 (Carrying case